Introduction
♦ PH Sensor electrode is made of internal reference electrode and glass electrode. It is used to measure the hydrogen ion concentration of a solution and display the pH value of the solution.
Usage
♦ Unscrew the pH electrode from protective bottle (with saturated KCl solution) before using.
♦ Check if there is air bubble in the glass ball.
♦ Swing to eliminate it.
♦ Try not to touch other objects.
Notes
♦ Rinse the electrode before every measuring. Do not wipe its glass ball using tissue. Otherwise it may cause damage to the electrode. It is better to clean the electrode using the testing solution.
♦ Keep the glass ball of the pH electrode wet in order to maintain the ion exchange process. It is required to preserve the glass ball in the KCI solution. Check the KCI solution’s volume periodically. If the electrode dries, immerse it into the KCI solution for 2 hours to make it wet.
♦ Protect the glass ball of the pH electrode. Do not knock, collide or rub it. Otherwise it may cause damage to the electrode.
♦ Keep electrode clean and dry when connecting and unplugging it. If not, it may lead to its insulation failure and make the result not accurate or make the experiment unsuccessful.
♦ We have found that the conductivity sensor has mild interference to this product. Using other devices with it will not cause this problem.
♦ The pH electrode has the limited service life, which mainly depends on its protection and testing solution. Do not store and preserve the electrode in the distilled water or the deionized water. Otherwise it may cause the saturated solution on the electrode to move. Never use the pH electrode in the extreme acid-based or alkaline-based solution or at the extreme temperature.
♦ Do not use the pH electrode in the absolute ethyl alcohol, concentrated sulphuric acid and other dehydration media since they may damage the hydration gel layer on the glass membrane surface. The pH electrode can not either be immersed in the neutral or the alkaline buffer solution. Long-term immersion in such solution may cause the pH glass membrane insensitive to respond.
♦ The material of PH electrode is PC. It will dissolve in some kinds of solution such as ethyl acetate, carbon tetrachloride, Cross-linked polythene and tetrahydrofuran. Those solution will damage the cover of electrode. You should use the electrode covered by glass.
♦ After long term using, the rate of data collecting will drop. Immerse the measuring side of electrode in 4%HF for 3-5s or diluted HCl solution for 1-2 minutes. Rinse it using distilled water and immerse it in potassium chloride (4M).
♦ This product can automatically compensate temperature. User does not need to make temperature compensation.